Part Number: L-530 | |
---|---|
Fuel Type | ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 LOW SULFUR FUEL OIL ASTM D975 ULTRA LOW SULFUR HEATING OIL/ DIESEL |
Heating Efficiency | 87% (AFUE Rating) |
Heating Rating | 22000 BTU/Hr (high)
15000 BTU/Hr (medium) 8000 BTU/Hr (low) |
Fuel Consumption | 0.165 Gal/Hr (High)
0.113 Gal/Hr (Medium) 0.060 Gal/HR (High) |
Size (WxHxD) | 19-5/8" x 23-5/8" x 16-1/2" |
Weight | 38 lbs (empty) |
Heating Area * | 920 Sq. Ft. at (0°F) 1150 Sq. Ft. at (20°F) |
Max. Length of Vent Pipe System |
Maximum 10 Ft., 3 bends or less |
Electrical Rating | 120 Volts AC, 60 Hz
Preheat: 240 Watts Burning: 40 Wattts |
Vent Hole Pipe | 2-3/4" - 3" Diameter |
Type of Tank | Exterior Tank |
Part Number: L-730 | |
---|---|
Fuel Type | ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 LOW SULFUR FUEL OIL ASTM D975 ULTRA LOW SULFUR HEATING OIL/ DIESEL |
Electric Rating | AC 120V, 60Hz |
Heating Efficiency | 87% (AFUE Rating) |
Heating Rating | 40000 BTU/Hr (high) 27000 BTU/Hr (medium) 15000 BTU/Hr (low) |
Size (WxHxD) | 30" x 27-1/2" x 16-3/4" |
Weight | 75 lbs (empty) |
Fuel Consumption | 0.301 gal/hr (high) 0.203 gal/hr (medium) 0.113 gal/hr (low) |
Heating Area * | 1670 Sq. Ft. at (0°F) 2000 Sq. Ft. at (20°F) |
Max. Length of Vent Pipe System | Maximum 10 ft., 3 bends or less |
Electrical Rating | 120 Volts, 60 Hz Preheat: 260 Watts Burning: 50 Watts |
Vent Hole Pipe | 2-3/4" - 3" diameter |
Type of Tank | Exterior Tank |
Part Number: L-60AT | |
---|---|
Type of Heater | Forced Flue Vented Heater (Antique Finish) |
Fuel Type | ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 LOW SULFUR FUEL OIL ASTM D975 ULTRA LOW SULFUR HEATING OIL/ DIESEL |
Electric Rating | 120V AC 60Hz
Preheat 270 Watts Buring 60 Watts |
Heating Efficiency | 87% (AFUE RATING) |
Heating Rating | 30,000 BTU/hr (high)
21,000 BTU/hr (medium) 12,000 BTU/hr (low) |
Fuel Consumption | 0.230 gal/hr (high)
0.161 gal/hr (medium) 0.095 gal/hr (low) |
Size (WxHxD) | 30" x 24" x 19" |
Weight | 77 lbs |
Heating Area *
|
1,250 Sq. Ft. at (0°F)
1,500 Sq. Ft. at (20°F) |
Vent Hole Pipe | 2-3/4" - 3" diameter |
Max. Length of
Vent Pipe System |
Maximum 10 ft, 3 bends or less |
Type of Tank | Exterior Tank (required) |
Model | OM-128HH |
Type | Combustion Type – Oil Pressure Vapor
Flue Pipe – Forced Flue / Chimney Vent Heating System – On-Demand Purpose – Hydronic Heating(1) |
Ignition | High Voltage Discharge Spark |
Fuel Type: | ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 LOW SULFUR FUEL OIL ASTM D975 ULTRA LOW SULFUR HEATING OIL/ DIESEL ASTM D396 No.2 FUEL OIL (HOME HEATING OIL) |
Efficiency | 87.1% |
Hot Water Input | 148,000 BTU/h |
Hot Water Output | 128,900 BTU/h |
Fuel Consumption | 1.05 gal./h |
Max. Hot Water Temperature | 176°F (approximately) |
Water Flow Rate/
Temperature Rise: |
6.2 gal./min. (40°F rise)
4.1 gal./min. (60°F rise) 3.1 gal./min. (80°F rise) |
Capacity of Heat Exchanger | 5.10 gal. |
Fuel System | External Tank(2) Gravity Fed |
Dimensions (W x H x D) | 12-5/8" x 27-3/4" x 22-1/2" |
Weight | 77 lbs. Empty |
Vent Pipe Hole | 4-3/4" diameter |
Max. Length of Vent Pipe | 10 ft., 3 bends or les |
Electric Rating | 120 Volts AC, 60 Hz
Ignition - 120W Burning - 98W |
Required Accessories | Fuel filter, Flue pipe installation kit (Part #20476440) or Chimney installation adapter kit (Part#20476430 - 5 inch kit or #20476415 - 4 inch kit) |
Safety Device | Over-heat protector,Ignitionsafety device, Heat exchangerbi-metalswitch, Dual-Temperature fuse, Fusible link valve |
Exhaust Air Temperature | Less than 500°F |
Nozzle | Quantity of Vapor - 0.85 GPH
Spraying Angle - 60° Spray pattern: Delavan Type XA |
Temperature Fuse | 282° F
|
Electric Current Fuse | 5A,
7A (for external circulation pump or accessory) |